TheProgramming Keycan quickly program multiple RFID locks to operate with the sameManager Credentials.
The images shown are for illustration purposes only and may not be an exact representation of your product.
Go to a lock already programmed to operate with the Manager Credentials.
Insert and hold the Programming Key in place for 10 seconds. The LED will turn on and a two-tone beep will be heard after 5 seconds, followed by two sets of two-tone beeps after 10 seconds.
Remove and reinsert the Programming Key. Two sets of two-tone confirmation beeps will be heard and the LED will turn off.
Insert the Programming Key to program each lock to operate with the same Manager Credentials. Two sets of two-tone beeps will be heard and the LED will flash to indicate successful programming.
End Express Registration mode.* Go to any programmed lock and override it with the Programming Key.
Deadbolt: Present hand to lock, then insert the Programming Key. The lock will engage. Present hand to lock again, then insert the Programming Key to return the bolt to the original position.
Deadlatch and Cam: Present hand to lock, then insert the Programming Key to operate the lock.
Orbit: For Orbit Deadbolt and Latch, present hand to lock. Insert the Programming Key, then immediately remove. A single beep will be heard. Reinsert the Programming Key within 1 to 5 seconds to operate the lock. To return an Orbit Deadbolt to the original position, follow the previous steps again.
*The Programming Key will continue to function in Express Registration mode until it is used to operate a lock.
Overrides user access
Allows management inspection
Provides external power
Programs Manager Keys to the lock
Sets lock functionality if applicable (lock must be a keypad with a Deadbolt)
A Manager Credential is used to manage a lock and is available as a Manager Key, RFID card, RFID fob, RFID sticker, RFID wristband, and Manager Digilock Mobile Access Credential.
Using the Programming Key, multiple locks can be quickly programmed to operate with the same Manager Credentials.
A solid, motor-driven bolt that extends into the locker frame.
A spring-loaded bolt that automatically secures when the door closes. It requires a valid credential to open but doesn’t need manual locking.
A rotating metal piece that engages or disengages the lock when turned. Locks with a Cam have a knob or handle to manually rotate the mechanism.
Note: A flat cam is shown for illustrative purposes.
Placing your hand near the RFID reader will make the LED flash red.
Shared Use is perfect for environments where multiple users need temporary access. An RFID credential allows anyone to use the unit, and once unlocked it's available for the next user. Locks configured in Shared Use may feature either a deadbolt or cam locking mechanism.
Placing your hand near the RFID reader will make the LED flash green.
Assigned Use is ideal for personal or dedicated access, where a specific individual or group is given an RFID credential to open a designated unit. The unit remains locked until the assigned user unlocks it using their credential. Assigned Use locks can be configured with a deadbolt, deadlatch, or cam.